MAX 400
Servo Amplifier Tuning Procedure
Mills using MAX 400 Amplifiers on KM 3 / 3P - V2
mills.
Tool Requirements:
a. Voltmeter
b. Small Screwdriver
Procedure:
1. Verify all Wago connectors are seated properly and that wiring is
correct prior to applying power to the Servo Amps.
2. Turn "ON" Control power and verify 115 VAC input to each servo
amplifier at P3 pins 9 and 10.
3. Apply BUSS power by depressing "Manual Mode", "Power On", and
"Start".
4. Verify 60 VAC input to each servo amplifier at P3 pins 6 and 7.
5. If axis accelerates toward full speed, switch off the AC power
(E-Stop) and reverse the tachometer leads connected at P3 pins 1 and
2.
6. Turn the (LAG) pot CW until the motor starts to oscillate, then
turn back CCW until it stops, then an additional 3 to 5 turns CCW.
7. Program positions or drill blocks that move the axis to be adjusted
at 25 IPM (inches per minute). Use the (VCS) pot to obtain a reading
of 0.900 VDC when connected between pins 1 and 2 of P1 on the
appropriate servo amplifier. Note: CCW increases voltage.
8. Adjust (BAL) to adjust the difference between directions to a
minimum. Continue in the CW direction. This should be no greater than
0.05 VDC difference. Recheck Step 8.
9. Calibrate the axis after all three servo amps have been setup and
verify that the position display reads 0.0000 and that the Marker Dot
is displayed. A blinking Marker Dot is OK !
Caution: Use Adjustments below only
after performing above procedure and not achieving the desired
results.
Presets Note: 16-Turn Pots
RMSI - (RMS Current Limit) - Full CW.
ILIM - (Internal Current Limit) - Full CW.
TACH - (Tach Gain) - Full CW.
BAL - (Balance Control) - Full CCW then 7.5 turns CW.
LAG - (Lag Control) - Full CCW.
VCS - (VCS Gain Scaling) - Full CW
Back to Tech Tips |
|